Ball valves for oxygen applications

Oxygen in technical processes has the potential to be extremely dangerous.

The adiabatic compression that may occur when a valve is closed or opened in an uncontrolled manner or just the presence of compressed oxygen alone can lead to a combustion reaction.

This is relevant in particular to non-metallic material such as seals or lubricants. Modified Hy-Lok valves for use with compressed oxygen are available to reduce this type of risk for people and equipment. These valves have been approved by a Notified Body.

Trapez Icon

Ball valves 110 OS Series

Application

The special oxygen version of the 110 Series with ball seats manufactured out of modified PTFE (110 OS Series) allows compressed oxygen to be shut-off safely.

Pressure/temperature (oxygen):

Up to 69 bar (1,000 psi) at 60 °C (140 °F)

Materials:

Stainless steel 316

Seat material:

Modified PTFE

  • 2-way version shut-off valve
  • Various connections (Hy-Lok compression fitting, NPT female thread)
  • Various bores and flow coefficients (0.84 ≤ cv ≤ 25.0)

  • In accordance with EN ISO 10297
  • Nitrogen at 69 bar (1000 psi) with a max. leak rate of 0.1 SCCM
  • Hydrostatic test of the housing at 1.5 times the permissible working pressure
  • Other tests on request

Durch Absenden des Formulars stimmen Sie der Verarbeitung Ihrer Daten gemäß Datenschutzerklärung zu.

Trapez Icon

Ball valve with a trunnion T OS Series

Application

The special oxygen version of the T Series with ball seats manufactured out of modified PEEK (T OS Series) allows highly compressed oxygen to be shut-off safely. 

T SERIES

Pressure/temperature (oxygen):

Up to 200 bar (2,900 psi) at 60 °C (140 °F)

Materials:

Stainless steel 316

Seat material:

Modified PEEK

 

  • 2-way version shut-off valve
  • Various connections (Hy-Lok compression fitting, NPT female thread)
  • Various flow coefficients (cv = 1.0 or 1.6)
  • Pneumatic drive on request

  • In accordance with EN ISO 10297
  • Nitrogen at 69 bar (1000 psi) with a max. leak rate of 0.1 SCCM
  • Hydrostatic test of the housing at 1.5 times the permissible working pressure
  • Other tests on request