Valves for oxygen applications

The adiabatic compression that may occur when a valve is closed or opened in an uncontrolled manner or just the presence of compressed oxygen alone can lead to a combustion reaction. This is relevant in particular to non-metallic material such as seals or lubricants. Modified Hy-Lok valves for use with compressed oxygen are available to reduce this type of risk for people and equipment. These valves have been approved by a Notified Body.


Trapez Icon

Needle valve – NV OS Series

Application

A selection of modified versions of NV Series valves with control spindle tips allow highly compressed oxygen to be shut-off and regulated in a controlled manner.

Safe shut-off for oxygen applications

The following versions in stainless steel 316 are available for a maximum working pressure of 200 bar and a maximum medium temperature of 60 °C.

Pressure/temperature (oxygen):

Up to 200 bar (2900 psi) at 60 °C (140 °F)

Material:

Stainless steel 316

Seal material:

Modified PTFE

Temperature fluctuations can necessitate adjustment of the gland packing.

  • Control cone

  • In accordance with EN ISO 10297
  • Nitrogen at 69 bar (1000 psi) with a max. leak rate of 0.1 SCCM
  • Hydrostatic test of the housing at 1.5 times the permissible working pressure
  • Other tests on request